Please read this product manual carefully before use and use it correctly and safely according to the requirements. | ||||||
Maintain this product; please save this product manual for future use. | ||||||
Introduction to healthy oxygen fans: | ||||||
The special device of the Healthy Oxygen Fan (AVM-30) can generate negative oxygen while generating active oxygen (O3). | ||||||
ion. | ||||||
This unique device makes this product mainly have the following functions: | ||||||
1) Sterilization function: | ||||||
At the same time, the right amount of active oxygen and negative ions exist in the air, and the two are combined to make them absorb in the negative ions. | ||||||
It is accompanied by various viruses and bacteria and is completely killed by the high oxidizing power of living oxygen. | ||||||
2) Smoke and dust removal function: | ||||||
Negatively charged negative ions in the electrode with positively charged smoke dust floating in the air | ||||||
And, let it be naturally deposited to achieve the purpose of dust removal. | ||||||
3) Destatic function: | ||||||
A large amount of negative ions in the air create a protective layer between people and TVs and computers. | ||||||
And neutralize high-voltage static electricity, effectively reducing the damage caused by the high static electricity of the TV computer. | ||||||
Reduce the damage of dust to TV and computer. | ||||||
"Safe" control protection of active oxygen concentration: | ||||||
In view of the fact that excessive oxygen (O3) may cause harm to the human body, the healthy oxygen fan adopts micro-electricity. | ||||||
Brain chip digital control security protection technology. | ||||||
1. According to the relationship between the active oxygen concentration PPM and the voltage V in the air, through the microcomputer crystal | ||||||
The chip automatically detects and records the data. When the active oxygen concentration reaches the safe concentration value, the microcomputer chip will | ||||||
Automatically cut off the oxygen generator power supply. | ||||||
2. The Oxygen Output Monitoring Circuit will automatically monitor whether the Oxygen Output is normal and not subject to accidents. | ||||||
In the case of control (eg, the machine turns on the active oxygen source, but no active oxygen is generated; the microcomputer chip | ||||||
The power supply command to disconnect the active oxygen generator has been issued, but there is oxygen generation.) The machine will automatically | ||||||
Alarm to indicate that the active oxygen output is faulty, and start the safety program to force the active oxygen generator input to be cut off. | ||||||
power supply. | ||||||
3. For safer monitoring of the concentration of active oxygen in the air, it will be delayed after opening the oxygen generating device. | ||||||
Start in three minutes. |