Model NO.: XLPE insulated cable
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001, CE, CCC, RoHS
Brand: Jiapu
Trademark: JP
Transport Package: Steel-Wood Drums
Specification: copper cable
Origin: China
HS Code: 8544492100
Model NO.: XLPE insulated cable
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001, CE, CCC, RoHS
Brand: Jiapu
Trademark: JP
Transport Package: Steel-Wood Drums
Specification: copper cable
Origin: China
HS Code: 8544492100
Two core Copper XLPE insulated cable priceSpecifications
electrical cableÂ
1. 4mm 6mm 10mm 25mm 35mm 70mm 90mmÂ
2.copper /Â cca/ ccc conductorÂ
3.pvc insulationÂ
4.(ho5vv-f)
 | 25mm, 35mm, 50mm, 70mm, 120mm, 150mm Multicore Copper Conductor XLPE Insulated PVC Sheath Armoured Power Cable Manufacturer  1.Product Description: (1).Specifications:     PVC/XLPE INSULATION POWER CABLE     State Grid     ISO 9001 standard     Internation compliance (2).Leading CABLE production base (3).Standard: IEC60502, BS, DIN, ASTM, GB12706-2008 standard. (4).Voltage: Up to 35KV(5).Conductor: Copper or Aluminum Conductor (6).Insulation: PVC or XLPE (7).Nominal Section Area(mm2): 1.5, 2.5, 4, 6, 10, 16, 25, 35 50 70 95 120 150 185 240 300 400 500 630 800  (8).Application: Medium Voltage Power Cable is used in fixed laying to distribute the electricity in the AC rated (9).Voltage: 35KV and under 35KV transmission line. (10).Package: Wooden Drum Package or Iron-wooden drum. |
---|
Construction:
Â
Conductor:Plain annealed copper or aluminium conductor
Shape: Circular Compacted or shaped Stranded Conductor (Class 2)
Insulation:VV/VV22Â Â PVCÂ
YJV/YJV22  XLPE (cross-linked polyethylene) rated at 90ºC
Colours for core indentification:
Single core-natural(black on request)
Two core-red,black
Three core-red, yellow,blue and black
Five core-red,yellow,blue,black and green/yellow
Armour:Galvanized steel wire armoured(SWA) or steel tape armoured(STA).
Sheath:PVC type ST2 to IEC 60502,colour black
Assembly:Two,three,four or five insulated conductors are laid up together if necessary filled with non-hygroscopic material compatible with the insulation.The filling may be omitted provided the outer shape of the cables remains practically circular and no adhesion occurs between cores and sheath.
Application:Â
Suitable for use in power distribution lines or fixed installations with rated voltage up to 0.6/1KV indoor or outdoor,enclosed in conduit, in underground duct where not subject to mechanical damage.
Non-armoured cables are designated for general use including underground bruial,where they are not likely to suffer mechanical damage.
Armoured cables are most suitable for underground burial where there is a risk of mechanical damage.
Standards
International:IEC 60502,IEC 60228
China:GB/T 12706,1-2008
Other standards such as BS,DIN and ICEA upon request
Certificates
CE,RoHS,CCC,SGS,ISO-9001 and more others at request
Technical data
Max.Conductor Temp:normal(70ºC),short circuit no more than 5s(160ºC when section-area below 300mm2,140ºC when section-area above 300mm2)
Min. Ambeent Temp:0ºCafter installation and only when cable is in a fixed position
Min. Bending Radius:20×O.D.
Operating Features
1, Max .Long-time operating temperature of PVC insulated cable is 70°C
Max .Long-time operating temperature of XLPE insulated cable is 90°C
2.Installing temperature of cable should not be less than 0°C
3, Max short-circuit temperature is not exceed 250°C, Not more than5 Sec.
4,Ambient temperature of installation is not lower than 0°C
5,With good chemical stabilities, such as resistance to acid, alkali, salt, oil and organic solvent and flam-retardant..
6,With light weight, good character, easy to installation and maintenance.
Istallation:
In air
1.As the single core cable laying in parallel,the distance between the cables center is 2Â times of the cable diameter,which cross sectional area of conductor<=182mm and 90mm,which cross sectional area of conductor>=240mm
2.Ambient temperature:40ºC
3.Max.Temperature of conductor:90ºC
4.Rating factors of current for ambient temperature.
Air temperature |
20ºC | 25ºC | 30ºC | 35ºC | 40ºC | 45ºC |
Rating factor | 1.29 | 1.22 | 1.15 | 1.08 | 1 | 0.91 |
Direct in ground
1.When the single core cable are installed separately,the distance between the cable's center is 2Â times of the cable diameter.
2.Ambient temperature:25ºC
3.Max. Temperature of conductor:90ºC
4.Soil therm our resistively:1ºC.m/W
5.Depth of laying:0.7m
6.Rating factors of current rating for ambient temperature.
Air temperature |
20ºC | 25ºC | 30ºC | 35ºC | 40ºC |
Rating factor | 1.04 | 1 | 0.96 | 0.92 | 0.87 |
Â
Norminal cross section size of conductor: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, , 500mm2  630mm2Â
Cores available: Single core, 2Â cores, 3Â cores, 4Â cores, 5Â cores, 3+1 cores, 3+2 cores, 4+1 cores.
Wire Gauge(No. of cores*section-area of each core)(mm2) |
wires of each core | thickness of insulation(mm) | thickness of steel tape armour(mm) | thickness of outer sheath(mm) | O.D.(mm) | Weight(kg/km) Â |
resistance of conductor at 20ºC (Ω/km)       |
||
Cu | Al | Cu | Al | ||||||
4*1.5 | Â | Â | Â | Â | Â | Â | Â | Â | Â |
4*2.5 | Â | Â | Â | Â | Â | Â | Â | Â | Â |
4*4 | 1 | 1 | 2*0.2 | 1.8 | 18.5 | 565 | 464 | 4.61 | 7.41 |
4*6 | 1 | 1 | 2*0.2 | 1.8 | 19.7 | 685 | 533 | 3.08 | 4.61 |
4*10 | 7 | 1 | 2*0.2 | 1.8 | 22.8 | 960 | 699 | 1.83 | 3.02 |
4*16 | 7 | 1 | 2*0.2 | 1.8 | 25.3 | 1273 | 851 | 1.15 | 1.91 |
4*25 | 7 | 1.2 | 2*0.2 | 1.8 | 30.5 | 1998 | 1374 | 0.327 | 1.2 |
4*35 | 7 | 1.2 | 2*0.2 | 1.9 | 33.5 | 2505 | 1602 | 0.524 | 0.868 |
4*50 | 19 | 1.4 | 2*0.5 | 2.0 | 35.2 | 3122 | 1832 | 0.387 | 0.641 |
4*70 | 19 | 1.4 | 2*0.5 | 2.2 | 38.7 | 4025 | 2220 | 0.268 | 0.443 |
4*95 | 19 | 1.6 | 2*0.5 | 2.4 | 44.7 | 5291 | 2842 | 0.193 | 0.32 |
4*120 | 37 | 1.6 | 2*0.5 | 2.5 | 49.4 | 6464 |
3370 |
0.153 |
0.253 |
4*150 | 37 | 1.8 | 2*0.5 | 2.6 | 53.7 | 7866 | 3998 | 0.124 | 0.206 |
4*185 | 37 | 2.0 | 2*0.5 | 2.8 | 58.9 | 9452 | 4772 | 0.991 | 0.164 |
4*240 | 61 | 2.2 | 2*0.5 | 3.0 | 61 | 11916 | 5727 | 0.0754 | 0.125 |
4*300 | 61 | 2.4 | 2*0.5 | 3.0 | 67 | 14118 | 6558 | 0.601 | 0.1 |
4*400 | 61 | 2.4 | 2*0.5 | 3.4 | 73.6 | 19950 | 9366 | 0.047 | Â Â |
Factory View:
Q&C and testing equipment:
Loading and packing details:
Customer visit:
What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
 Two core Copper XLPE insulated cable price
Specifications
electrical cableÂ
1. 4mm 6mm 10mm 25mm 35mm 70mm 90mmÂ
2.copper /Â cca/ ccc conductorÂ
3.pvc insulationÂ
4.(ho5vv-f)
 | 25mm, 35mm, 50mm, 70mm, 120mm, 150mm Multicore Copper Conductor XLPE Insulated PVC Sheath Armoured Power Cable Manufacturer  1.Product Description: (1).Specifications:     PVC/XLPE INSULATION POWER CABLE     State Grid     ISO 9001 standard     Internation compliance (2).Leading CABLE production base (3).Standard: IEC60502, BS, DIN, ASTM, GB12706-2008 standard. (4).Voltage: Up to 35KV(5).Conductor: Copper or Aluminum Conductor (6).Insulation: PVC or XLPE (7).Nominal Section Area(mm2): 1.5, 2.5, 4, 6, 10, 16, 25, 35 50 70 95 120 150 185 240 300 400 500 630 800  (8).Application: Medium Voltage Power Cable is used in fixed laying to distribute the electricity in the AC rated (9).Voltage: 35KV and under 35KV transmission line. (10).Package: Wooden Drum Package or Iron-wooden drum. |
---|
Construction:
Â
Conductor:Plain annealed copper or aluminium conductor
Shape: Circular Compacted or shaped Stranded Conductor (Class 2)
Insulation:VV/VV22Â Â PVCÂ
YJV/YJV22  XLPE (cross-linked polyethylene) rated at 90ºC
Colours for core indentification:
Single core-natural(black on request)
Two core-red,black
Three core-red, yellow,blue and black
Five core-red,yellow,blue,black and green/yellow
Armour:Galvanized steel wire armoured(SWA) or steel tape armoured(STA).
Sheath:PVC type ST2 to IEC 60502,colour black
Assembly:Two,three,four or five insulated conductors are laid up together if necessary filled with non-hygroscopic material compatible with the insulation.The filling may be omitted provided the outer shape of the cables remains practically circular and no adhesion occurs between cores and sheath.
Application:Â
Suitable for use in power distribution lines or fixed installations with rated voltage up to 0.6/1KV indoor or outdoor,enclosed in conduit, in underground duct where not subject to mechanical damage.
Non-armoured cables are designated for general use including underground bruial,where they are not likely to suffer mechanical damage.
Armoured cables are most suitable for underground burial where there is a risk of mechanical damage.
Standards
International:IEC 60502,IEC 60228
China:GB/T 12706,1-2008
Other standards such as BS,DIN and ICEA upon request
Certificates
CE,RoHS,CCC,SGS,ISO-9001 and more others at request
Technical data
Max.Conductor Temp:normal(70ºC),short circuit no more than 5s(160ºC when section-area below 300mm2,140ºC when section-area above 300mm2)
Min. Ambeent Temp:0ºCafter installation and only when cable is in a fixed position
Min. Bending Radius:20×O.D.
Operating Features
1, Max .Long-time operating temperature of PVC insulated cable is 70°C
Max .Long-time operating temperature of XLPE insulated cable is 90°C
2.Installing temperature of cable should not be less than 0°C
3, Max short-circuit temperature is not exceed 250°C, Not more than5 Sec.
4,Ambient temperature of installation is not lower than 0°C
5,With good chemical stabilities, such as resistance to acid, alkali, salt, oil and organic solvent and flam-retardant..
6,With light weight, good character, easy to installation and maintenance.
Istallation:
In air
1.As the single core cable laying in parallel,the distance between the cables center is 2Â times of the cable diameter,which cross sectional area of conductor<=182mm and 90mm,which cross sectional area of conductor>=240mm
2.Ambient temperature:40ºC
3.Max.Temperature of conductor:90ºC
4.Rating factors of current for ambient temperature.
Air temperature |
20ºC | 25ºC | 30ºC | 35ºC | 40ºC | 45ºC |
Rating factor | 1.29 | 1.22 | 1.15 | 1.08 | 1 | 0.91 |
Direct in ground
1.When the single core cable are installed separately,the distance between the cable's center is 2Â times of the cable diameter.
2.Ambient temperature:25ºC
3.Max. Temperature of conductor:90ºC
4.Soil therm our resistively:1ºC.m/W
5.Depth of laying:0.7m
6.Rating factors of current rating for ambient temperature.
Air temperature |
20ºC | 25ºC | 30ºC | 35ºC | 40ºC |
Rating factor | 1.04 | 1 | 0.96 | 0.92 | 0.87 |
Â
Norminal cross section size of conductor: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, , 500mm2  630mm2Â
Cores available: Single core, 2Â cores, 3Â cores, 4Â cores, 5Â cores, 3+1 cores, 3+2 cores, 4+1 cores.
Wire Gauge(No. of cores*section-area of each core)(mm2) |
wires of each core | thickness of insulation(mm) | thickness of steel tape armour(mm) | thickness of outer sheath(mm) | O.D.(mm) | Weight(kg/km) Â |
resistance of conductor at 20ºC (Ω/km)       |
||
Cu | Al | Cu | Al | ||||||
4*1.5 | Â | Â | Â | Â | Â | Â | Â | Â | Â |
4*2.5 | Â | Â | Â | Â | Â | Â | Â | Â | Â |
4*4 | 1 | 1 | 2*0.2 | 1.8 | 18.5 | 565 | 464 | 4.61 | 7.41 |
4*6 | 1 | 1 | 2*0.2 | 1.8 | 19.7 | 685 | 533 | 3.08 | 4.61 |
4*10 | 7 | 1 | 2*0.2 | 1.8 | 22.8 | 960 | 699 | 1.83 | 3.02 |
4*16 | 7 | 1 | 2*0.2 | 1.8 | 25.3 | 1273 | 851 | 1.15 | 1.91 |
4*25 | 7 | 1.2 | 2*0.2 | 1.8 | 30.5 | 1998 | 1374 | 0.327 | 1.2 |
4*35 | 7 | 1.2 | 2*0.2 | 1.9 | 33.5 | 2505 | 1602 | 0.524 | 0.868 |
4*50 | 19 | 1.4 | 2*0.5 | 2.0 | 35.2 | 3122 | 1832 | 0.387 | 0.641 |
4*70 | 19 | 1.4 | 2*0.5 | 2.2 | 38.7 | 4025 | 2220 | 0.268 | 0.443 |
4*95 | 19 | 1.6 | 2*0.5 | 2.4 | 44.7 | 5291 | 2842 | 0.193 | 0.32 |
4*120 | 37 | 1.6 | 2*0.5 | 2.5 | 49.4 | 6464 |
3370 |
0.153 |
0.253 |
4*150 | 37 | 1.8 | 2*0.5 | 2.6 | 53.7 | 7866 | 3998 | 0.124 | 0.206 |
4*185 | 37 | 2.0 | 2*0.5 | 2.8 | 58.9 | 9452 | 4772 | 0.991 | 0.164 |
4*240 | 61 | 2.2 | 2*0.5 | 3.0 | 61 | 11916 | 5727 | 0.0754 | 0.125 |
4*300 | 61 | 2.4 | 2*0.5 | 3.0 | 67 | 14118 | 6558 | 0.601 | 0.1 |
4*400 | 61 | 2.4 | 2*0.5 | 3.4 | 73.6 | 19950 | 9366 | 0.047 | Â Â |
Factory View:
Q&C and testing equipment:
Loading and packing details:
Customer visit:
What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
Â
Off-grid, home energy storage, back-up, UPS,Home Series,Home battery series,HomeKit, renewable energy, hybrid system,household
Shenzhen Enershare Technology Co.,Ltd , https://www.enersharepower.com